AM093 Digital Indicator
For force measurement signals need to be converted into digital communication signals, standard analog output signals, simple control occasions.
Analog output signal can be selected 0-20mA or 4-20mA 0-10V, 1-5V, digital communication interface can be selected RS485 or RS232.
Product Description
Characteristics and Application
For situations where force measurement signals need to be converted into digital communication signals, standard analog output signals, and simple controls
Analog output signal can be selected 0-20mA or 4-20mA 0-10V, 1-5V, digital communication interface can be selected RS485 or RS232
Double row 6-digit LED digital tube displays real-time measurement value, peak value, output current value and 1 I/O status information respectively
The controller has the function of judging the upper limit, middle limit and lower limit
I/O has 4 inputs and 6 outputs, with customizable input and output ports
It can drive the controller output through the upper computer and partially replace the PLC
The controller power supply adopts DC24V power supply, the voltage range is 5V, which is safer and more stable
Open panel installation, panel area is only 110mm (width) x 62mm (height)
Application field: automobile press assembly, automatic assembly, 3C product testing, new energy product assembly, medical testing, robot, mold assembly and other industrial testing, measurement and control system.
Mounting Dimension
Parameter List
Display window | Double row 6-digit LED display | Zero temperature drift | ≤10μV/°C |
Readability | 1/90000 | Excitation | 5 volts DC |
Output linear |
<0.002% |
Power supply |
24±5VDC |
The overall accuracy | better than 0.01% | Total power consumption | ≤10W |
A/D conversion speed | ≤400 times/SEC | Operating temperature range | -20~70 degrees Celsius |
Acceptance sensitivity | -3.6-+3.6 mVN | Single weight | 0.5 kg |
Input load |
1-8 3502 Sensor unit |
Cloth |
aluminum alloy |
Output specifications |
10V10~10V 14~20mA |
Protection level |
IP65 |
Full scale temperature drift |
≤10ppm /C |