AM088 Digital Indicator
Mainly used in PLC control system or DCS system. In the computer management control system, the instrument transmits the weight to the PLC or DCS computer via a serial port or Ethernet port or PROFINET industrial Ethernet.
Product Description
Characteristics and Application
Mainly used in PLC control system or DCS. Computer management control system, the weight of the instrument is transferred to the PLC or DCS, computer via serial port or Ethernet port or PROFINET industrial Ethernet;
Supports platform-level access of 1 to 4 channels with a maximum AD rate of 200 times/second.
100000 high display accuracy, 6000e CMC certified accuracy.
1 RS232/485 serial port, 2 Ethernet ports (100M), with switch function.
Support MODBUS-RTU& MODBUS-TCP.
Support PROFINET, TCP/IP.
Support mobile APP or computer tools for meter configuration and calibration.
Standard industrial DIN rail mounting (DIN)
Application field: automobile press assembly, automatic assembly, 3C product testing, new energy product assembly, medical testing, robot field, mold assembly and other industrial testing, measurement and control system.
Mounting Dimension
Parameter List
Precision Class | III Precision | Connection method | Four or six wires |
Proof | 6 digit 7 segment red LED display | Calibration | Weight calibration, support remote calibration |
Weighing condition |
Gross, net, dynamic, zero. Channel switching and communication status |
Filtered radio waves | Adjustable with 5-level digital filtering |
Button or key (on the device) | Function key, tare weight, clear, Return to zero, switch | Serial port communication | COM1-RS232485 is standard.Supports MODBUS-RTU |
A/D conversion speed | 200 times/SEC/SEC | Ethernet |
Two Ethernet ports, support TCP continuous weight output. PROFINET |
Acceptance sensitivity |
0 to 19 mVN |
Bluetooth |
connection to mobile APP for configuration, calibration and maintenance |
Nonlinear and temperature coefficient |
≤0.0015%FS; ≤ 5pm /C |
Operating temperature range |
-10~40C, 95% relative humidity |
Sensor excitation voltage |
5VDC can provide up to 150mA of current |
Supply |
220VAC or 24VDC |
Input load |
4*3502 sensor Load cell |
Mounting |
DIN standard industrial rail |