WM008C Dynamic Loading Module

There  are  screw  holes  on  the  upper  and lower  mounting plates of the weighing module for fixing the sensor module. Please do not loosen any nuts on the weighing module product during installation.

Send Inquiry E-mail

Product Description

1. Capacity

Total weight of tank: 36 TONS

Capacity for single module: 15T

Total capacity of 4pcs is 60T

Material: Load cell/17-4PH Stainless Steel; Metal Module/304 Stainless Steel

 

Specifications Technique
Nomial Load 1,2,5,3,5,7,5,10t
Rated Output 2.0±1%mV/V
Zero Balance ±2% F.S.
Non-linearity 0.03%F.S.
Hysteresis 0.03%F.S.
Repeatability 0.03%F.S.
Creep(30min) 0.03%F.S.
Temp.effect on output 0.05%F.S./10℃
Temp.effect on zero 0.05%F.S./10℃
Input Impedance 780±20Ω
Output Impedance 780±10Ω
Insulation ≥5000MΩ/100VDC
Recommended excitation 5V
Maxmum excitation 15V
Compensated temp range -10~40℃
Operation temp range -20~60℃
Safe overload 150%F.S.
Ultimate Overload 200%F.S.
IP Class IP68
Cable size
φ5-4mm

 

 

 

 

2. Weighing Module

Item:T008C

 

Digital Junction Box

Item:T086B

 

Indicator

Item:T063 (RS485 optional with LED display)

 

 

3. How to connect the parts

 

 

(1) Weighing controller and junction box connection:

According to the schematic diagram, the cable color should be connected with the corresponding terminal;

Colour of Cable Red Green Yellow White Black
Terminal E+ S+ GND/SHLD S- E-

 

(2) Connect the load cell to the junction box;

 

 

Connecting wiring:

Colour of Cable Red Green Yellow White Black
Terminal E+ S+ GND S- E-

Note: The serial number is required to correspond to the connecting cable.

 

(3) Power supply and communication connection

 

 

Power supply of indicator: DC 24V

Communication support: 0-10V, RS485/ Mod-BUS

 

4. How to install a weighing module

 

 

A: After  the  weighing  platform  and  all  installation  accessories  are  ready, please  install  the  weighing  module  product  and  the  weighing  platform together;

B: There  are  screw  holes  on  the  upper  and lower  mounting plates of the weighing module for fixing the sensor module. Please do not loosen any nuts on the weighing module product during installation;

C: After all the installation work is in place, please completely loosen the A and B nuts when preparing to debug or use the weighing platform so that the platform is in a completely free-floating state.

 

5. Installation and debugging precautions

(1) During the installation and debugging process, it is not allowed to cut the original cables on our products, otherwise it will cause signal errors;

Do not use the sensor body as a force support point during our installation, otherwise it will cause signal errors;

(2) After all products are installed in place, loosen the two nuts (A, B) on the top of the module screw so that the weighing platform is completely floating;

If re-transportation is required, please tighten nuts A and B again to protect the sensor from external damage;

(3) The full scale range of a single sensor is 15 tons. Do not apply more than 150% of the safe overload range to a single product;

(4) Please check the foundation condition before installation: the plane drop of each installation point should be controlled within 3 mm, and the levelness of the same foundation surface should be controlled within 1mm/m; the bearing capacity of the installation base must be greater than the measuring range of the sensor.

(5) This set of products is a high-precision weighing unit. During installation, transportation, debugging, and use, please prevent anyone from standing on the sensor or weighing platform. It is prohibited to use violent actions such as kicking or stomping, otherwise the product will be damaged. Our company is not responsible.

 

6. Debugging

(1) Before the product leaves the factory, the error between each product has been calibrated with high precision and no adjustment is required;

(2) All parameters of the weighing controller have been set before the product leaves the factory. Please do not modify the internal parameters;

(3) After the weighing platform is completely installed and the nut on the top of the module has been loosened, please reset the instrument to zero (press and hold the zero  key).  Then  it  can  be  used  for  normal  weighing.  It  has  been calibrated with standard weights before leaving the factory. Do not recalibrate.

(4) After use, if you need to recalibrate, please use a standard weight or an actual accurately weighed object as a weight  reference. The  recommended weight is 50% of the measuring range.

 

During  installation,  debugging,  and  use,  if  you  have  any  questions,  please contact our company in time to avoid improper operation and damage to the product. Thank you for your understanding and support.

 

Send Inquiry

For inquiries about our products or pricelist, please leave your email to us and we will be in touch within 24 hours.

Verify Code